4.4.1 Using Multiple M-Series Readers With Same Cradle
If you want to use several M-Series readers with the same OM-Gryphon™ cradle,
you must first Bind the cradle with one of the readers (see previously described
configuration procedure).
Successive readers can be associated with the same cradle by following the
configuration procedure substituting the Bind command with Join (step 5).
5.
Join
Ì$+RN1$-NÎ
The green LED on the Gryphon™ M will blink: the reader is ready to be
positioned onto the cradle. Complete step 6.
END of procedure.
CAUTION
If the cradle is not
Bound
to a reader, its address assumes a
random value which can cause conflicts and malfunctions to other
cradles within its range.