Symbologies
122
Magellan
TM
3200VSi
Code 93 — continued
Length Control
Fixed Length Decoding—
When fixed length decoding is enabled, the scanner will decode a bar
code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding—
When variable length decoding is enabled, the scanner will decode a
bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.
Code 93 Length 1, Length 2 Programming Instructions
1. See Length 1, Length 2 Programming Instructions on page 154 for detailed instructions on
setting this feature
.
START / END
PROGRAMMING bar codes
Variable Length Decoding
DEFAULT
Fixed Length Decoding
NOTE
For Code 93 bar codes, only the data characters
are included in the length calculations.
START / END
PROGRAMMING bar codes
DEFAULT SETTING FOR THIS FEATURE: 01
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 50