EasyManua.ls Logo

Datalogic MAGELLAN 3200VSI

Datalogic MAGELLAN 3200VSI
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
156
Magellan
TM
3200VSi
Physical Properties
Electrical Parameters
Environmental Parameters
Other Parameters
Parameter Specification
Dimensions (Scanner only): 6” x 5.6” x 3.3” (WxHxD)
Weight (Scanner) 1 lb 4.6 oz (0.584kg)
Parameters Specification
AC Power Requirements AC Input: 90-264 VAC, 47~63Hz
AC Power Consumption Real Power
Operating (Maximum) 8.75Watts
Operating (Nominal) 2.8Watts
Sleep mode 2.0Watts
DC Power Requirements Reference for POT user
Input Voltage 7 to 14 V DC
Operating Current and Power at 12V DC Current Power
Maximum Inrush 715mA 8.6 Watts
Maximum Continuous 545mA 6.6 Watts
Nominal Scanner Only 180mA 2.2 Watts
Sleep, Scanner Only 123mA 1.5 Watts
Parameter Specification
Contaminants
Water and Dust
IP5x
Temperature Ranges:
Operating 32 F to +104 F (0 C to +40 C)
Storage -40 F to +158 F (-40 C to +70C)
Ambient Light Indoor 0 - 6,000 lux
Ambient Light Outdoor 0 - 86,100 lux
Humidity 5% to 95% non-condensing
Beeper/Speaker 70-90dBA at a distance of 3’-3” (1 meter)
Vibration Retail/Office
Parameter Specification
EAS Support YES (Checkpoint)

Table of Contents

Other manuals for Datalogic MAGELLAN 3200VSI

Related product manuals