Interleaved 2 of 5 (I 2 of 5)
Product Reference Guide
189
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional I 2 of 5 check
character. When disabled, any check character in label is treated as a data character.
ENTER/EXIT PROGRAMMING MODE
I 2 of 5 Check Character Calculation = Disable
I 2 of 5 Check Character Calculation = Check Standard
(Modulo 10)
I 2 of 5 Check Character Calculation = Check German Parcel
I 2 of 5 Check Character Calculation = Check DHL
I 2 of 5 Check Character Calculation = Check Daimler Chrysler
I 2 of 5 Check Character Calculation = Check Bosch
DEFAULT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QD2100 and is the answer not in the manual?

Datalogic QD2100 Specifications

General IconGeneral
Scanner TypeLinear Imager
Environmental SealingIP42
Operating Temperature0 to 50 °C / 32 to 122 °F
Scan Rate270 scans/sec
InterfaceRS-232, Keyboard Wedge, USB
Drop ResistanceWithstands drops from 1.5 m / 5.0 ft onto concrete
Print Contrast Ratio15%
Decode CapabilityAll standard 1D barcodes
Resolution0.102 mm / 4 mils
Storage Temperature-20 to 70 °C / -4 to 158 °F
Humidity5 to 95% non-condensing
Electrical SafetyEN60950-1
EMCEN 55022
Light SourceLED (red)