268 QuickScan® QD2100
Decode Capability
UPC/EAN/JAN, P2 /P5 GS1-128 add-ons; Code 39; Code 39 Full ASCII;
Code 32 (Italian Pharmacode); Code 128; ISBT 128; I 2 of 5; Standard 2
of 5; Code 11; Codabar; GS1-128; Code 93; MSI; GS1 DataBar Omnidi-
rectional, GS1 DataBar Limited, GS1 DataBar Expanded; EAN 13 ISBN;
Datalogic 2 of 5; Follet 2/5; Code 4, code 5.
Interfaces Supported
RS-232 Std., RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM 46xx (ports 5B
and 9B), USB Com Std., USB Keyboard, USB Alternate Keyboard, USB
Keyboard Apple, USB-OEM, Keyboard Wedge (AT with or w/o Alternate
Key, IBM AT PS2 with or w/o Alternate Key, PC-XT, IBM 3153, IBM Termi-
nals 31xx, 32xx, 34xx, 37xx make only and make break keyboard, and
Digital Terminals VT2x, VT3xx and VT4xx).
User Environment
Operating Temperature 32° to 122° F (0° to 50° C)
Storage Temperature -40° to 158° F (-40° to 70° C)
Humidity 5% to 95% relative humidity, non-condensing
Drop Specifications Withstands multiple 5 ft./1.524 m drops to concrete.
Ambient Light Immunity
Immune to direct exposure of normal office and factory lighting conditions,
as well as direct exposure to sunlight.
Contaminants
Spray/rain
Dust/particulates
IEC 529-IPX2
IEC 529-IP5X
Beeper Volume User-selectable: three levels
Beeper Tone (frequency) User-selectable: three tones
Electrostatic Discharge Conforms to ±20 kV air/direct discharge and ±8 kV of contact discharge.
Regulatory
Electrical Safety
USA: UL 60950, Canada: CAN/CSA-C22.2 No. 60950, EN60950/
IEC60950, NOM-019-SCFI
EMI/RFI
FCC Part 15 Class B, ICES-003 Class B, European Union EMC Directive,
Australia Class B, Taiwan EMC, Japan VCCI/MITI, Korea KCC