USE AND FUNCTIONING
3
3.5.3 Resetting the Skorpio
TM
Windows CE
There are several reset methods for the Skorpio.
A warm boot terminates an unresponsive application and clears the working RAM,
but preserves both the file system and the registry.
A cold boot forces all applications to close and clears working RAM and files not
resident on the persistent flash memory. Registry is restored from persistent memory
if available or returned to factory default.
A Clean Boot restores the Skorpio to factory configuration: both the registry and the
file system return to factory default.
Warm Boot
A warm boot closes all applications, clears the working RAM, but preserves the file
system and registry. If an application hangs, initiate a warm boot to terminate the
application.
To perform a warm boot, press and hold (for a while) the following keys
simultaneously:
Cold Boot
A cold boot is a complete reset of the Skorpio in which all applications are forcibly
closed and the RAM is completely cleared. Registry is restored from persistent
memory if a saved copy is available (see 3.8.2) and RAM file system completely
erased. You will lose any applications and data (included registry) which are not
stored in persistent flash memory.
A cold boot is necessary when the Windows CE operating system locks up and the
warm boot command does not work.
To perform a cold boot, press these keys simultaneously:
Clean Boot
A clean boot is a cold boot that causes the device to be restored to factory
configuration. The Skorpio will reset to its factory configuration, clear the working
RAM and initialize the file system. You will lose any applications and data stored in
persistent flash memory. At the next startup the system will ask to recalibrate the
touch screen.
33

Table of Contents

Other manuals for Datalogic Skorpio

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Skorpio and is the answer not in the manual?

Datalogic Skorpio Specifications

General IconGeneral
BrandDatalogic
ModelSkorpio
CategoryPDA
LanguageEnglish

Related product manuals