EasyManuals Logo

Datalogic Smart-VS Plus User Manual

Datalogic Smart-VS Plus
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
DEVICE CONTROL COMMANDS
PRODUCT REFERENCE GUIDE 54
CRTJB (CReaTeJoB)
Allows you to start a configuration session. The device switches from the “Running”
state to the “Configuration” state. By sending the command, the auto-setup of the pho-
tometric parameters and the focus distance is automatically done based on the object
positioned in front of the device. The auto-setup procedure requires the object to be
statically positioned in front of the sensor.
Syntax:
CRTJB;BankId;JobName<CR><LF>
Possible return codes:
Success → Command successful.
InvalidInput → The specified bank is out of the range (0-31)
OtherInProgress → Another asynchronous task is in progress. This task cannot be
started. Finalize the previously started task.
AlreadyInConfiguration → The device is already in configuration, it is not possible
to start a new one. Finalize the previous configuration by completing it or exiting
without saving.
Failed → The device is already in the configuration state (HMI, WebApp).
MDFJB (MoDiFyJoB)
It allows to add images to a previously configured job thus using the device's incremen-
tal training functionality. The device switches from the “Running” state to the “Configu-
ration” state.
Syntax:
MDFJB;BankId<CR><LF>
BankId: Bank number on which to create the new job (may not be the current bank).
Reply:
MDFJB;ReturnCode <CR><LF>
Possible return codes
:
Success → Command successful.
InvalidInput → The specified bank is out of the range (0-31) or no editable jobs are
saved in the specified bank.
AlreadyInConfiguration → no editable jobs are saved in the specified bank. Final-
ize the previous configuration by completing it or exiting without saving.
Failed → The device is already in the configuration state (HMI, WebApp).
CAUTION: To return to the “Running” state, you need to perform one of the
following operations:
Complete the job creation procedure
Interrupt the procedure by exiting with the appropriate command
Close the client connection with the device
CAUTION: To return to the “Running” state, you need to perform one of the
following operations:
Complete the job creation procedure
Interrupt the procedure by exiting with the appropriate command
Close the client connection with the device

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Smart-VS Plus and is the answer not in the manual?

Datalogic Smart-VS Plus Specifications

General IconGeneral
BrandDatalogic
ModelSmart-VS Plus
CategorySecurity Sensors
LanguageEnglish

Related product manuals