REFERENCE MANUAL
> SC6000

Table of Contents

Other manuals for Datalogic SC6000

Questions and Answers

  • M
    Micheal PageAug 19, 2025
    What to do if the Datalogic SC6000 is not transmitting data to the host?
    • J
      Jeremy NelsonAug 19, 2025
      If the Datalogic Controller isn't transmitting to the host, ensure the serial Main/Aux cable is connected and the wiring is correct. When using the Main RS232 or RS485 interface, ensure the reference ground is connected to GND_ISO, being careful that it differs from the GND power ground. Confirm that the serial host settings match the serial device settings. When using the Main interface, the Tx Data and Rx Data LEDs should light up during data transfer.
  • M
    Mary ReyesAug 21, 2025
    Why is the data transferred to the host incorrect from Datalogic SC6000 Controller?
    • L
      Laura BassAug 22, 2025
      If data transferred to the host from the Datalogic Controller are incorrect, corrupted, or incomplete, verify the HEADER, TERMINATOR, SEPARATOR, and FILL CHAR values in the Genius™ program within the DATA COMMUNICATION SETTINGS/DATA FORMAT folder. Also, check the CODE FIELD LENGTH value and ensure the COM port parameters are correctly assigned.
  • A
    Angela BoyerAug 25, 2025
    What to do if Datalogic SC6000 Controller reader is not triggered in Serial On Line Mode?
    • K
      Kent GarciaAug 25, 2025
      If the Datalogic Controller reader is not triggered in Serial On Line Mode, verify that serial on line is enabled as the “On Line options” parameter value in the OPERATING MODE folder of the Genius™ program. Also, check if the Start-Stop strings are correctly assigned and the serial trigger source is correctly connected and configured.
  • C
    catherine50Aug 26, 2025
    Why Datalogic Controller does not respond correctly to the expected external signal end?
    • M
      Mary KennedyAug 26, 2025
      If the Datalogic Controller does not respond correctly to the expected external signal end in On Line Mode and Serial On Line Mode, check the “Reading Phase Timeout” parameterization in the OPERATING MODES folder of the Genius™ software configuration program.
  • M
    Michael MillsAug 27, 2025
    What to do if "PS” LED is lit but nothing happens on Datalogic SC6000 Controller?
    • D
      Daniel FullerAug 27, 2025
      If the "PS” LED is correctly lit but nothing happens (no reading results) on the Datalogic Controller in On Line Mode 1, ensure that the software configuration is consistent with the application condition, such as the operating mode. Check related parameters in the OPERATING MODES folder of the Genius™ software configuration program.
  • W
    William FitzgeraldAug 29, 2025
    How to fix Ethernet LED not lit on Datalogic SC6000?
    • D
      Dustin HaysAug 30, 2025
      If the Ethernet LED is not lit on the Datalogic Controller, verify the HUB connection and the Genius™ settings.
  • D
    Debbie BrooksAug 31, 2025
    What to do if data does not appear on the terminal from Datalogic SC6000?
    • G
      Gregory JohnsonAug 31, 2025
      If data does not appear on the terminal from the Datalogic Controller, enable the DATA TX parameter in the DATA COMMUNICATION SETTINGS/MAIN- AUXILIARY PORT within the Genius™ program.
  • S
    Sharon MooreSep 2, 2025
    What to do if "PS” LED is not lit on Datalogic SC6000 Controller?
    • A
      allen86Sep 2, 2025
      If the "PS” LED is not lit on the Datalogic Controller in On Line Mode 1 when the external trigger activates, check if you are referring to the 25-pin connector of the PWO. Also, verify if the sensor is connected to the PWO PS input and if power is supplied to the photo sensor.
  • R
    rileyjohnSep 4, 2025
    How to fix Datalogic Controller when the power LED is not lit?
    • A
      Abigail CarsonSep 5, 2025
      If the “Power On” LED is not lit on the Datalogic Controller, check if the power is connected. If you are using a power adapter, ensure it is connected to the PWO 25-pin cable.
  • E
    Eric GilbertSep 6, 2025
    What to do if Datalogic SC6000 Controller is not transmitting data to the host?
    • M
      Manuel MillerSep 7, 2025
      If the Datalogic Controller isn't transmitting data to the host, ensure the serial Main/Aux cable is connected and correctly wired. For Main RS232 or RS485, verify the reference ground is connected to GND_ISO, ensuring it differs from the power ground. Check that serial host settings match the device settings. When using the Main interface, the Tx Data and Rx Data LEDs should light up during data transfer.

Datalogic SC6000 Specifications

General IconGeneral
ModelSC6000
RAM4 GB DDR3L
Storage64 GB SSD
Ethernet2 x Gigabit Ethernet
Input Voltage24 VDC
Serial Ports2 x RS232
Video OutputHDMI
ConnectivityUSB, Serial
Operating Temperature-10°C to 50°C