    Michael AtkinsonSep 8, 2025
    What to do if Datalogic SC6000 Controller does not respond correctly to the external signal end?
    • A
      Angela BrightSep 8, 2025
      If the Datalogic Controller does not respond correctly to the expected external signal end in On Line Mode and Serial On Line Mode, check the “Reading Phase Timeout” parameterization in the OPERATING MODES folder of the Genius™ software configuration program.
  • J
    Jon WallSep 12, 2025
    How to fix if data do not appear on the terminal from Datalogic SC6000 Controller?
    • J
      Jason CampbellSep 12, 2025
      If data do not appear on the terminal from Datalogic Controller, enable the DATA COMMUNICATION SETTINGS/MAIN- AUXILIARY PORT\DATA TX parameter in the Genius™ program.
  • K
    Kristina LloydSep 12, 2025
    How to troubleshoot Ethernet LED not lit on Datalogic SC6000 Controller?
    • S
      Steven MorrisSep 12, 2025
      If the Ethernet LED is not lit on the Datalogic Controller, verify the HUB connection and the Genius™ settings (see par. 3.4).
  • J
    josephlopezSep 14, 2025
    How to fix the “Power On” LED if it is not lit on Datalogic Controller?
    • C
      Christopher OwensSep 14, 2025
      If the “Power On” LED is not lit on the Datalogic Controller, check if the power is connected. If you're using a power adapter, ensure it's connected to the PWO 25-pin cable.
  • D
    Daryl DanielSep 16, 2025
    What to check if "PS” LED is not lit on Datalogic Controller?
    • M
      michael82Sep 16, 2025
      If the "PS” LED is not lit on the Datalogic Controller in On Line Mode 1 (when the external trigger activates), carefully check if you are referring to the 25-pin connector of the PWO. Ensure the sensor is connected to the PWO PS input and that power is supplied to the photo sensor.