EasyManua.ls Logo

Datalogic Smart-VS Plus - STBCK (Storebackup); FNZJBF (Finalazejobfile)

Datalogic Smart-VS Plus
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TCP/IP COMMUNICATION
65 SMART-VS PLUS
STBCK (SToreBaCKup)
It allows to save the binary file containing the device backup on the device's flash mem-
ory. The file must be previously uploaded to the exchange area. The device switches
from the “Running” state to the “Configuration” state.
Syntax:
STBCK;Force <CR><LF>
Force:
forces the flash to be overwritten.
Reply:
STBCK;Returncode<CR><LF>
Possible return codes:
Success → command successful.
AlreadyInConfiguration → a configuration has already started and the file cannot
be loaded.
InvalidInput → corrupted file or not loaded (exchange area empty).
Failed → the file loaded in the exchange area is not a file containing a BackUp.
FNZJBF (FiNalaZeJoBFile)
Finalizes the asynchronous command to create a binary file containing a single job
(“
CRTJBF (CReaTeJoBFile)" on page 63).
Syntax:
FNZJBF<CR><LF>
Reply:
FNZJBF;ReturnCode;FileSizeByte <CR><LF>
FileSizeByte: Returns the size of the created file in bytes. The size of the file to be down-
loaded from the device, due to the base64 encoding, can be obtained with the following
formula:
or divided by 3, rounded up to the nearest integer, then multiplied by 4.
Possible return codes
:
Success → command successful.
NotInProgress → no asynchronous tasks in progress.
OtherInProgress → another asynchronous task is in progress.
Failed → package creation failed.
VALUE FORCE
0
False
1
True
CAUTION: To return to the “Running” state, you need to perform one of the
following operations:
Finalize the creation of the package containing the job using the
FNZBST command
Close the client connection with the device