82 A-Class
Step
Action Displayed Message Comment
O
Using the DOWN ARROW
Key set the ‘Paper’ level to
the value determined in
the previous step and
press the ENTER Key.
Repeat this step for the
‘Gap’ (or ‘Mark’) and the
‘Empty’ value.
PAPER SENSOR LEVEL
P* 198 G*000 E*000
È
GAP SENSOR LEVEL
P* 198 G*084 E*000
È
EMPTY SENSOR LEVEL
P* 198 G*084 E*014
-Or, for reflective media:
PAPER SENSOR LEVEL
P* 015 G*000 E*000
È
GAP SENSOR LEVEL
P* 015 G*181 E*000
È
EMPTY SENSOR LEVEL
P* 015 G*181 E*213
The selection will change to
indicate the item for entry.
P
Press the ESC Key
repeatedly to exit the
menu and, when
prompted, save the
changes.
SAVE CHANGES?
NO YES
Selecting YES saves the
settings, while NO discards
them.
(continued)