58 I-Class
4.1.7 Diagnostics
HEX DUMP MODE Most commonly used for troubleshooting.
Prints data and instructions received from
the host rather than interpreting them as
label formats; see Section 6.2.
ENABLE
Prints raw ASCII data received from the
host rather than executing the commands.
DISABLE
Executes and prints label formats (normal
operating mode).
OPTIONS TESTING Tests currently installed options
TEST PRESENT SENSOR
Performs a functional test of the Present
Sensor circuitry.
TEST CUTTER
Performs a functional test of the optional
cutter mechanism and circuitry.
PERFORM TEST
1 TIME
The cutter will cycle 1, 10 or 100 times
(selectable). The results of each attempt
will be displayed.
MONITOR GPIO INPUT
TEST GPIO OUTPUT
TEST SCANNER
Performs a functional test of the Scanner.
SCAN TEST
Enters read once mode.” A bar code is
read and the decoded results are displayed.
ALIGNMENT TEST
Enters “constant read mode.” Bar codes
are read; decoded results are displayed;
and, a read-count is incremented.
PRINT TEST RATE (min)
000 (0-120)
The number of minutes to delay between
the printing of batches of labels in Quick
Test Mode.