System Settings (continued)
FAULT HANDLING
When a fault condition (ribbon out, media out, etc.) is detected, this setting
determines the level of intervention and the disposition of the label being printed at
the time the fault occurred.
LEVEL
Selects the printers action, the action required by the operator, and the label’s
reprint status.
STANDARD
Printing stops and a fault message is displayed. After the problem is corrected, the
FEED Key must be pressed to clear the fault. The label in process is reprinted.
VOID AND RETRY
Depending upon the RETRY COUNT, one of the following actions when faulted:
If the Retry Count setting has not been exceeded,VOID’ is printed on the label in
process and reprinting occurs automatically;
If the Retry Count has been exceeded, printing stops and a fault message is
displayed. After the problem is corrected, the FEED Key must be pressed to clear
the fault. The label in process is reprinted; or,
If the CANCEL Key is pressed the operator now has the option of canceling the
reprint:
To allow the reprint, press the ESCAPE Key or to cancel the reprint, press the
ENTER Key (the operator now has the option of canceling the entire label batch
by pressing the ENTER Key again.)
Note: VOID will not be printed when insufficient space exists for the height of the text (see VOID
DISTANCE, below) or if the fault occurred after the entire label was completed (i.e., when the label
reaches its Present Distance at or above the TOF).
NO REPRINT
Printing stops and a fault message is displayed. After the problem is corrected, the
FEED Key must be pressed to clear the fault. The label in process is not reprinted.
VOID DISTANCE
0.50 in (.10-2.00)
Sets the distance to backup the faulted label to print ‘VOID’ on its trailing edge,
which also indirectly establishes the font size of the void message.
RETRY COUNT
1 (0-3)
Establishes the number of times the printer will attempt to reprint a label. If the last
label printed in this count has been voided, the printer will stop and display a fault
message.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax M-Class and is the answer not in the manual?

Datamax M-Class Specifications

General IconGeneral
Print MethodThermal Transfer/Direct Thermal
Resolution203 dpi, 300 dpi
Print Speed6 IPS (152 mm/s)
InterfaceUSB, Serial, Ethernet, Parallel
Media SensorReflective and Transmissive
Supported Media TypesLabels, Tags
Media Thickness0.0025" (0.0635 mm)