4: Radio Programming
PRC1099A-MSOP 4-17
LQA DECY LQA Decay Rate. Radio frequency propagation through
the atmosphere is changing constantly, and the LQA
evaluation score for each channel changes. This selection
is for selecting the time that each LQA score remains
valid, unless it is updated.
1. Toggle the TUNE knob to toggle between 1, 2, 4, or 8
hours. Selecting NO means the score remains valid
indefinitely.
2. Press WHIP TUNE to save the setting.
BER THD Bit Error Rate Threshold. For indicating the amount of bit
error allowed before an 8-bit word is rejected.
1. Toggle the TUNE knob to increase or decrease the
threshold between 00 and 48.
2. Press WHIP TUNE to save the setting.
GLY THD Golay Threshold. For indicating the amount of word
encoding error allowed before a word is rejected.
1. Toggle the TUNE knob to increase or decrease the
threshold between 0 and 4. The default is 3.
2. Press WHIP TUNE to save the setting.
ERR THD Error Threshold. For selecting the number of errors
allowed before a word is rejected.
1. Toggle the TUNE knob to increase or decrease the
threshold between 0 and 4. The default is 3.
2. Press WHIP TUNE to save the setting.
MEM DUMP Memory Dump. To erase ALE memory data. A partial
memory dump erases LQA data and a full memory dump
erases all ALE data in the radio.
1. Toggle the
TUNE knob to toggle between F (full) and P
(partial).
2. Press
WHIP TUNE to save the setting.
Selection Description