Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity Recommended Action
RAM voltage
regulator's
temperature is not
within threshold
RAM_INVALID_VR_TE
MPERATURE
Node.Ram.INV
ALID_VR_TEM
PERATURE
SIO07.04.000
0002
5 (Critical) 3
(Error)
Ensure that the server and
its environment are
properly cooled and that all
the chassis fans are
functional.
RAM voltage
regulator's voltage is
not within threshold
RAM_INVALID_VR_VOL
TAGE
Node.Ram.INV
ALID_VR_VOLT
AGE
SIO07.04.000
0003
5 (Critical) 3
(Error)
Ensure that the server and
its environment are
properly cooled and that all
the chassis fans are
functional. If the system
still issues an alert, the
DIMM may be faulty, and
may have to be replaced.
The node
temperature has
exceeded the
configured threshold
NODE_INVALID_TEMPE
RATURE
Node.Node.INV
ALID_TEMPER
ATURE
SIO07.05.000
0001
5 (Critical) 3
(Error)
Ensure that the server and
its environment are
properly cooled and that all
the chassis fans are
functional.
The voltage values
on the node are not
within the
configured threshold
NODE_INVALID_VOLTA
GE
Node.Node.INV
ALID_VOLTAG
E
SIO07.05.000
0002
5 (Critical) 3
(Error)
1. Verify that the power
supply is functioning
correctly, and then try to
replace a port in the Power
Distribution Unit or check
with external power. 2.
Replace the power cable. 3.
Replace the Power Supply
Module.
Unable to connect
to monitoring agent
(BMC)
NODE_FAILED_TO_CO
NNECT_TO_BMC
Node.Node.FAI
LED_TO_CON
NECT_TO_BM
C
SIO07.05.000
0004
5 (Critical) The BMC IP address or
User credentials do not
respond to AMS queries.
Verify network connectivity
from the AMS to the BMC
IP address, and check that
the BMC admin user and
password have not been
tampered with. Contact
customer support for
assistance if the problem
persists.
SDC is not installed
on this node
NODE_WITH_NO_SDC Node.Node.NO
DE_WITH_NO_
SDC
SIO07.05.000
0005
3 (Error) Consider installing an SDC
on this node, so that it can
use VxFlex OS volumes
Unable to connect
to monitoring agent
(SVM)
NODE_FAILED_TO_CO
NNECT_TO_SVM
Node.Node.FAI
LED_TO_CON
NECT_TO_SV
M
SIO07.05.000
0006
5 (Critical) The SVM IP address or
User credentials do not
respond to AMS queries.
Check the SVM state in
SNMP Trap Support
308 Dell EMC VxFlex Ready Node AMS User Guide