Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity Recommended Action
vCenter and try to open the
SSH or the console to it.
Then check the message
log for errors.
Unable to connect
to monitoring agent
(ESX)
NODE_FAILED_TO_CO
NNECT_TO_ESX
Node.Node.FAI
LED_TO_CON
NECT_TO_ESX
SIO07.05.000
0007
5 (Critical) The ESX IP address or User
credentials do not respond
to AMS queries. Check the
ESX state in vCenter and
try to open the SSH or the
console (via BMC http) to
it. Then check the
messages log for errors.
Unable to connect
to monitoring agent
(host)
NODE_FAILED_TO_CO
NNECT_TO_HOST
Node.Node.FAI
LED_TO_CON
NECT_TO_HO
ST
SIO07.05.000
0007
5 (Critical) The ESX IP address or User
credentials do not respond
to AMS queries. Check the
ESX state in vCenter and
try to open the SSH or the
console (via BMC http) to
it. Then check the
messages log for errors.
Unable to connect
to monitoring agent
(VCenter)
NODE_FAILED_TO_CO
NNECT_TO_VCENTER
Node.Node.FAI
LED_TO_CON
NECT_TOVCE
NTER
SIO07.05.000
0008
5 (Critical) Ensure that the vCenter
configuration is correct,
and ensure that the node's
Mgmt port is routable to
the vCenter IP address
Node serial number
has changed
NODE_SERIAL_NUMBE
R_CHANGE
Node.Node.SE
RIAL_NUMBER
_CHANGE
SIO07.05.000
0009
3 (Error) The S/N of the
Motherboard does not
match the IP address of the
ESX. Either the SATADOM
was moved to a new server
or the motherboard was
replaced. It is also possible
that a new server that has
the same IP addresses and
the same user and
password, but was not
installed using the AMS
flow, exists in the network.
EMC does not support such
field replacement cases.
Such cases should be
solved by replacing nodes
using EMC-recommended
procedures. For more
information, contact
Customer Support.
SNMP Trap Support