EasyManua.ls Logo

Dell EMC VxFlex Ready Node - Page 318

Dell EMC VxFlex Ready Node
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 35 VxFlex Ready Node–specific Alerts in SNMP, VxFlex OS GUI, REST, and
ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert Message in
SNMP Trap
Alert Code
(for ESRS)
Severity Recommended Action
Node serial number
has changed
NODE_SERIAL_NU
MBER_CHANGE
Node.Node.SERIAL
_NUMBER_CHANG
E
SIO07.05.000
0009
3 (Error) The S/N of the Motherboard
does not match the IP
address of the ESX. Either
the SATADOM was moved to
a new server or the
motherboard was replaced. It
is also possible that a new
server that has the same IP
addresses and the same user
and password, but was not
installed using the AMS flow,
exists in the network. EMC
does not support such field
replacement cases. Such
cases should be solved by
replacing nodes using EMC-
recommended procedures.
For more information,
contact Customer Support.
RFcache pool state
is "Not Started"
XTREMCACHE_INV
ALID_STATE
Node.Node.XTREM
CACHE_INVALID_S
TATE
SIO07.05.000
0010
3 (Error) Check the Read Flash Cache
pool state. The cache device
might be misconfigured. In
this case, remove the cache
device from the cache pool
and add it back again.
Host certificate is
about to expire
HOST_CERTIFICAT
E_ABOUT_TO_EXP
IRE
Node.Node.HOST_
CERTIFICATE_ABO
UT_TO_EXPIRE
SIO07.05.000
0014
3 (Error) Renew the AMS certificate
and then run "renew
certificate" process
CMOS battery state
is invalid
NODE_INVALID_C
MOS_BATTERY
Node.Node.Invalid_
Cmos_Battery
SIO07.05.000
0015
3 (Error) Check the node's CMOS
battery. It may need to be
replaced.
The node is not
being managed by
the current AMS.
NODE_NOT_MANA
GED_BY_AMS
Node.Node.Node_N
ot_Managed_By_A
ms
SIO07.05.000
0016
5 (Critical) Verify that the node is not
being managed by a different
AMS.
Failed to connect to
the SVM due to
authentication
failure
NODE_FAILED_TO
_CONNECT_TO_S
VM_AUTH_FAILED
Node.Node.Node_F
ailed_To_Connect_
To_Svm_Auth_Faile
d
SIO07.05.000
0017
5 (Critical) Change the SVM's root
password to be the one set
by the AMS
Failed to connect to
the host. The SSH
key has been
changed, and is not
trusted by the AMS.
NODE_FAILED_TO
_CONNECT_TO_H
OST_SSH_KEY_MI
SMATCH
Node.Node.Node_F
ailed_To_Connect_
To_Host_Ssh_Key_
Mismatch
SIO07.05.000
0018
5 (Critical) This is a security issue.
Remove the node, and add
the node again to the AMS.
SNMP Trap Support
318 Dell EMC VxFlex Ready Node AMS User Guide