Explanation of parts: Each rack ear contains two elongated holes, enabling you to fasten it to the rack (using the M5
thumbscrews) in the most accessible mounting holes.
1 Place the desired module (whichever module you want to be the bottom module of the library) onto the rack-mount
shelves. From the front of the rack, lift the module onto the shelf and gently slide it into the rack. Slide the module to
the back of the rack, so that the front of the module is flush with the mounting holes.
2 From the back of the rack, secure the module to the rack-mount shelves by tightening the two silver thumbscrews that
are attached to the rear of the rack-mount shelves.
3 Install the right rack ear. At the front of the library:
a Open the I/E station door. At the lower right corner of the module is a vertical slot. Insert the hinge of the right
rack ear into the slot and then position the holes of the rack ear flush with the rack rail.
1 Hinge of rack ears
b Using two M5 thumbscrews, fasten the rack ear to the rack. The thumbscrews should thread through the holes in
the rack shelves and fasten completely and evenly.