Installing, Removing, and Replacing
file:///T|/htdocs/stor-sys/ML6000/en/html/ch08.htm[9/17/2012 1:50:35 PM]
1 Latch hooks, locked
2 FC I/O blade
3 Cover plate on empty bay
4 FC I/O blade LEDs
7 Make sure cover plates are installed over any unused bays in the 9U Library Expansion Module.
Caution: Bays that are not populated with blades must contain a cover plate. If the cover plate is not installed,
FC I/O blade temperature errors will occur.
8 Cable the library as described in Connecting Library FC Cables to FC I/O Blades.
9 Save the library configuration (see Saving the Library Configuration).
Removing an FC I/O Blade
These instructions explain how to remove an FC I/O blade from your library. You can remove an FC I/O blade while the library
is powered on.
Note: The library will generate a RAS ticket when you remove the I/O blade. If you do not want the library to
generate a RAS ticket, you can power down the I/O blade before removing it. See Controlling FC I/O Blade Power.
Required tools: None