Ethernet & Sequencer Programming SM15K
14 / 44 DELTA ELEKTRONIKA B.V. rev. Aug. 2019
To set the limits of the current:
Syntax : SYSTem:LIMits:CURrent<sp><NR2>,<boolean><term> Off = disabled, On = enabled
To read the last setting:
Syntax : SYSTem:LIMits:CURrent?
To set the limits of the negative current:
Syntax : SYSTem:LIMits:CURrent:NEGative<sp><NR2>,<boolean><term> Off = disabled,
On = enabled
To read the last setting:
Syntax : SYSTem:LIMits:CURrent:NEGative?
To set the limits of the power:
Syntax : SYSTem:LIMits:POWer<sp><NR2>,<boolean><term> Off = disabled, On = enabled
To read the last setting:
Syntax : SYSTem:LIMits:POWer?
To set the limits of the negative power:
Syntax : SYSTem:LIMits:POWer:NEGative<sp><NR2>,<boolean><term> Off = disabled,
On = enabled
To read the last setting:
Syntax : SYSTem:LIMits:POWer:NEGative?
5.6.3 Front Panel Highlight
Syntax : SYSTem:FROntpanel:HIGhlight
- Display on front will blink for about 2 seconds.
- Buzzer on front is on for about 2 seconds.
5.6.4 Front Panel Lock
It is possible to lock either the Menu, or lock the Menu and the Controls.
Syntax : SYSTem:FROntpanel[:STAtus]<sp><boolean><term>
Boolean = 0, 1, OFF (Unlocked), ON (Locked)
To read the last setting:
Syntax : SYSTem:FROntpanel[:STAtus]?<term>
Both the Menu and the Controls can be locked. To set whether the Menu, or the Menu and the Controls will
be locked use the command:
Syntax : SYSTem:FROntpanel:CONtrols<sp><boolean><term>
To read the last setting:
Syntax : SYSTem:FROntpanel:CONtrols?
Boolean = 0 (Menu), 1 (Menu & Controls), OFF (Menu), ON (Menu & Controls)
5.6.5 Remote method
The SM15K allows the user to switch to either local or remote programming.
The programming of CV, CC or CP can be done individually, so for example one or two can be controlled
via Ethernet interface and the others via the encoder on the frontpanel. Any combination is possible. Hence
there are three commands to set the programming source:
To set the CV programming source:
Syntax : SYSTem:REMote:CV[:STAtus]<sp><setting><term> setting = Remote or Local
1
To read the last setting:
Syntax : SYSTem:REMote:CV[:STAtus]?<term>
To set the CC programming source:
Syntax : SYSTem:REMote:CC[:STAtus]<sp><setting><term> setting = Remote or Local
1
To read the last setting:
Syntax : SYSTem:REMote:CC[:STATus]?<term>
To set the CP programming source:
Syntax : SYSTem:REMote:CP[:STAtus]<sp><setting><term> setting = Remote or Local
1
To read the last setting:
Syntax : SYSTem:REMote:CP[:STATus]?<term>
1) The settings Remote or Local are equal to the settings Ethernet or Front.

Table of Contents

Other manuals for Delta Elektronika SM15K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Elektronika SM15K and is the answer not in the manual?

Delta Elektronika SM15K Specifications

General IconGeneral
BrandDelta Elektronika
ModelSM15K
CategoryPower Supply
LanguageEnglish

Related product manuals