AS Series Module Manual
8- 18
_8
Multiple load cells connected in parallel are connected to a single load cell module.
Lo ad cell
CH1
CH2
Lo ad cell
Lo ad cell
Lo ad cell
Lo ad cell
Lo ad cell
Lo ad cell
Loa d ce ll
Note 1: Please connect on the power supply module and on the load cell module to a system
ground, and then ground the system ground or connect the system ground to a distribution box.
Note 2: If multiple load cells are connected in parallel, the total impedance should be greater than 40 Ω.