Chapter  8  Load Cell  Module AS02LC 
8- 35 
(5)  Alarm settings 
 
 
8.5  Troubleshooting 
8.5.1  Error Codes 
Error 
Code 
Description 
A
 D LED 
indicator 
ERROR LED 
indicator 
16#1605 
Hardware failure    OFF  ON 
16#1607 
The external voltage is abnormal.  OFF  ON 
16#1801 
The external voltage is abnormal.  OFF  Blinking 
16#1802 
Hardware failure  OFF 
Blinking 
16#1807 
The driver board is abnormal.  OFF 
Blinking 
16#1808 
The weight measured by CH1 exceeds the maximum weight that
can be measured, or the voltage of SEN is incorrect. 
Run: blinking 
Stop: OFF 
Blinking 
16#1809 
The weight measured by CH1 exceeds the maximum weight that
can be measured. 
16#180A 
CH1 is adjusted incorrectly. 
16#180B 
The weight measured by CH2 exceeds the maximum weight that
can be measured, or the voltage of SEN is incorrect. 
16#180C 
The weight measured by CH2 exceeds the maximum weight that
can be measured. 
16#180D 
CH2 is adjusted incorrectly.