Parameters ASDA-B2-F
7-60 September, 2015
7
P5-20 AC0 Acceleration / Deceleration Time (Number #0)
ddress: 0528H
0529H
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 200
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format: DEC Data Size: 16-bit
Settings:
The setting time of acceleration / deceleration in DMCNET mode, which is the time required to
accelerate from 0 to 3000 r/min.
P5-21 AC1 Acceleration / Deceleration Time (Number #1)
A
ddress: 052AH
052BH
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 300
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format: DEC Data Size: 16-bit
Settings:
Please refer to P5-20 for the setting of acceleration / deceleration time in DMCNET mode.
P5-22 AC2 Acceleration / Deceleration Time (Number #2)
A
ddress: 052CH
052DH
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 500
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format: DEC Data Size: 16-bit
Settings:
Please refer to P5-20 for the setting of acceleration / deceleration time in DMCNET mode.
P5-23 AC3 Acceleration / Deceleration Time (Number #3)
A
ddress: 052EH
052FH
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 600
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format: DEC Data Size: 16-bit
Settings:
Please refer to P5-20 for the setting of acceleration / deceleration time in DMCNET mode.
P5-24 AC4 Acceleration / Deceleration Time (Number #4)
ddress: 0530H
0531H
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 800
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format: DEC Data Size: 16-bit
Settings:
Please refer to P5-20 for the setting of acceleration / deceleration time in DMCNET mode.
P5-25 AC5 Acceleration / Deceleration Time (Number #5)
ddress: 0532H
0533H
Operational
Interface:
Panel / Software Communication
Related
Section:
-
Default: 900
Control
Mode:
DMCNET
Unit: ms Range:
1 ~ 65500
Format: DEC Data Size: 16-bit
Settings:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-B2-F Series and is the answer not in the manual?

Delta ASDA-B2-F Series Specifications

General IconGeneral
BrandDelta
ModelASDA-B2-F Series
CategoryServo Drives
LanguageEnglish

Related product manuals