ASDA-M Chapter 8 Parameters
Revision December, 2014 8-49
P1-10 SP2
Internal Speed Command 2Internal
Speed Limit 2
Address: 0114H
0115H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 6.3.1
Operational
Interface
Panel / Software Communication
Default
2000
Control
Mode
ST
Unit
0.1r/min
Range
-60000 ~ +60000
Data Size
32bit
Format
DEC
Example
Internal Speed Command: 120 = 12 r/min
Internal Speed Limit: Positive value and
negative value is the same. Please refer
to the following description.
Settings
Internal Speed Command 2: The setting of the second internal
speed command
Internal Speed Limit 2: The setting of the second internal speed
limit
Example of inputting internal speed limit:
Speed limit
setting
value of
P1-10
Allowable
Speed
Range
Forward
Speed Limit
Reverse
Speed Limit
1000
-100 ~ 100
r/min
100 r/min -100 r/min
-1000
P1-11 SP3
Internal Speed Command 3Internal
Speed Limit 3
Address: 0116H
0117H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 6.3.1
Operational
Interface
Panel / Software Communication
Default
3000
Control
Mode
ST
Unit
0.1r/min

Table of Contents

Other manuals for Delta ASDA-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-M Series and is the answer not in the manual?

Delta ASDA-M Series Specifications

General IconGeneral
BrandDelta
ModelASDA-M Series
CategoryServo Drives
LanguageEnglish

Related product manuals