Chapter 8 Parameters ASDA-M
8-60 Revision December, 2014
Settings
Inertia ratio to servo motor (rotary motor):
(J_loadJ_motor)
Among them:
J_motor: rotor inertia of the servo motor
J_load: Total equivalent of inertia of external mechanical load.
Load weight ratio to servo motor (linear motor) (*it will be
available soon):
(M_loadM_motor)
Among them:
M_motor: the weight of the servo motor
M_load: Total equivalent weight of mechanical loading
P1-38 ZSPD Zero Speed Range Setting
Address: 014CH
014DH
Parameter
Attribute
Parameter for individual axis
Related Section:
Table 8.2
Operational
Interface
Panel / Software Communication
Default
10.0 100
Control
Mode
ALL
Unit
1 r/min 0.1 r/min
Range
0.0 ~ 200.0 0 ~ 2000
Data Size
16bit
Format
One decimal DEC
Example
1.5 = 1.5 r/min 15 = 1.5 r/min
Settings
Setting the output range of zero-speed signal (ZSPD). When the
forward / reverse speed of the motor is slower than the setting
value, the digital output will be enabled.
P1-39 SSPD Target Motor Detection Level
Address: 014EH
014FH
Parameter
Attribute
Parameter for individual axis
Related Section:
Table 8.2
Operational
Interface
Panel / Software Communication
Default
3000

Table of Contents

Other manuals for Delta ASDA-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-M Series and is the answer not in the manual?

Delta ASDA-M Series Specifications

General IconGeneral
BrandDelta
ModelASDA-M Series
CategoryServo Drives
LanguageEnglish

Related product manuals