P1-48 MCOK
Operation Selection of Motion Reached
(DOMC_OK)
Address: 0160H
0161H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0x0000
Control
Mode
PR
Unit
-
Range
0x0000 ~ 0x0011
Data Size
16bit
Format
HEX
Settings
Control selection of digital output DO.MC_OK (DO code is 0x17).
The format of this parameter: 00YX
X0: It will not remain the digital output status
1: It will remain the digital output status
Y0: Alarm, AL380 (position deviation) is not
working
1: Alarm, AL380 (position deviation) is
working