ASDA-M Chapter 8 Parameters
Revision December, 2014 8-69
Range
0 ~ 65535
Data Size
16bit
Format
DEC
Settings
In speed mode, when the deviation between the speed feedback
and the command is smaller than the setting value of P1-47 and
exceed the setting time of P1-49, DO: SP_OK is ON. Whenever
the deviation exceeds the setting range of P1-47, the time count
will be reset.
P1-50
Reserved
Address: 0164H
0165H
P1-51
Reserved
Address: 0166H
0167H
P1-52 RES1 Regenerative Resistor Value
Address: 0168H
0169H
Parameter
Attribute
Parameter for three axes
Related Section:
Section 2.7
Operational
Interface
Panel / Software Communication
Default
Determined by the model. Please refer to
the following table.
Control
Mode
ALL
Unit
Ohm
Range
10 ~ 750
Data Size
16bit
Format
DEC
Settings
Model Default
1.5 kW (included)
or below
40
2 kW 20