Chapter 8 Parameters ASDA-M
8-70 Revision December, 2014
P1-53 RES2 Regenerative Resistor Capacity
Address: 016AH
016BH
Parameter
Attribute
Parameter for three axes
Related Section:
Section 2.7
Operational
Interface
Panel / Software Communication
Default
Determined by the model. Please refer to
the following table.
Control
Mode
ALL
Unit
Watt
Range
0 ~ 3000
Data Size
16bit
Format
DEC
Settings
Model Default
1.5 kW (included)
or below
60 W
2 kW 100 W
P1-54 PER Position Completed Range
Address: 016CH
016DH
Parameter
Attribute
Parameter for individual axis
Related Section:
Table 8.2
Operational
Interface
Panel / Software Communication
Default
12800
Control
Mode
PTPR
Unit
Pulse
Range
0 ~ 1280000
Data Size
32bit
Format
DEC
Settings
In position mode (PT), if the deviation pulse number is smaller
than the setting range (the setting value of parameter P1-54),
DO.TPOS is ON.
In position register (PR) mode, if the deviation between the target
position and the actual motor position is smaller than the setting
range (the setting value of parameter P1-54), DO.TPOS is ON.

Table of Contents

Other manuals for Delta ASDA-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-M Series and is the answer not in the manual?

Delta ASDA-M Series Specifications

General IconGeneral
BrandDelta
ModelASDA-M Series
CategoryServo Drives
LanguageEnglish

Related product manuals