P1-55 MSPD Maximum Speed Limit
Address: 016EH
016FH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
Same as the rated speed of each model
Control
Mode
ALL
Unit
r/min
Range
0 ~ max. speed
Data Size
16bit
Format
DEC
Settings
The default of the max. speed of servo motor is set to the rated
speed.
P1-56 OVW Output Overload Warning Level
Address: 0170H
0171H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
120
Control
Mode
ALL
Unit
%
Range
0 ~ 120
Data Size
16bit
Format
DEC
Settings
The setting value is 0 ~ 100, if the servo motor continuously
outputs the load and is higher than the setting proportion (P1-56),
the early warning for overload (DO is set to 10, OLW) will occur.
If the setting value is over 100, it will disable this function.
P1-57 Reserved
Address: 0172H
0173H
P1-58 Reserved
Address: 0174H
0175H

Table of Contents

Other manuals for Delta ASDA-M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-M Series and is the answer not in the manual?

Delta ASDA-M Series Specifications

General IconGeneral
BrandDelta
ModelASDA-M Series
CategoryServo Drives
LanguageEnglish

Related product manuals