Chapter 8 Parameters ASDA-M
8-114
Revision December, 2014
Range:
1 ~ (2
29
-1)
Data Size:
32bit
Format:
DEC
Settings:
The numerator of electronic gear ratio can be selected via DI.GNUM0
and DI.GNUM1 (Please refer to table 8.1). If DI.GNUM0 and
DI.GNUM1 are not set, P1-44 will automatically be the numerator of
electronic gear ratio. Please switch GNUM0 and GNUM1 in stop
status to avoid the mechanical vibration.
P2-61 GR5 Gear Ratio (Numerator) (N3)
Address: 027AH
027BH
Parameter
Attribute:
Parameter for individual axis
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
128
Control
Mode:
PT
Unit:
Pulse
Range:
1 ~ (2
29
-1)
Data Size:
32bit
Format:
DEC
Settings:
Please refer to the description of P2-60.