Chapter 8 Parameters ASDA-M
8-114
Revision December, 2014
Range
1 ~ (2
29
-1)
Data Size
32bit
Format
DEC
Settings
The numerator of electronic gear ratio can be selected via DI.GNUM0
and DI.GNUM1 (Please refer to table 8.1). If DI.GNUM0 and
DI.GNUM1 are not set, P1-44 will automatically be the numerator of
electronic gear ratio. Please switch GNUM0 and GNUM1 in stop
status to avoid the mechanical vibration.
P2-61 GR5 Gear Ratio (Numerator) (N3)
Address: 027AH
027BH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
128
Control
Mode
PT
Unit
Pulse
Range
1 ~ (2
29
-1)
Data Size
32bit
Format
DEC
Settings
Please refer to the description of P2-60.