ASDA-M Chapter 8 Parameters
Revision December, 2014 8-115
P2-62 GR6 Gear Ratio (Numerator) (N4)
Address: 027CH
027DH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
128
Control
Mode
PT
Unit
Pulse
Range
1 ~ (2
29
-1)
Data Size
32bit
Format
DEC
Settings
Please refer to the description of P2-60.
P2-63
Reserved
Address: 027EH
027FH
P2-64
Reserved
Address: 0280H
0281H
P2-65 GBIT Special-bit Register
Address: 0282H
0283H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
PTPRS
Unit
-
Range
0 ~ 0xFFFF
Data Size
-
Format
-