3 Functions of Devices in DVP-PM
DVP-PM Application Manual
3-27
Special
D
Function
10M 20D 20M
OFF
Ø
ON
MANU
Ø
AUTO
AUTO
Ø
MANU
Attrib. Latched Default
Page
number
PWM pulse width setting on X axis (low word)
â—‹
╳ ╳
â—‹-
- - R/W
NO
0 -
Target position (I) of X axis: P(I) (high word)
â—‹ â—‹ â—‹ â—‹
- - R/W
NO
0 -
Lower bound of CAM synchronized output (high word)
╳
â—‹ â—‹ â—‹-
- - R/W
NO
0 -
D1839
PWM pulse width setting on X axis (lhigh word)
â—‹
╳ ╳
â—‹-
- - R/W
NO
0 -
Operation speed (I) of X axis: V(I) (low word)
â—‹ â—‹ â—‹
1,000 - - R/W
NO
1,000 -
D1840
CAM max frequency (low word)
╳
â—‹â—‹
1,000 - - R/W
NO
1,000 -
Operation speed (I) of X axis: V(I) (high word)
â—‹â—‹â—‹
1,000 - - R/W
NO
1,000 -
D1841
CAM max frequency (high word)
╳
â—‹â—‹
1,000 - - R/W
NO
1,000 -
Target position (II) of X axis: P(II) (low word)
â—‹
â—‹ â—‹
0 - - R/W
NO
0 -
Upper bound of CAM synchronized output (low word)
╳
â—‹ â—‹
0 - - R/W
NO
0 -
D1842
PWM cycle setting on X axis (low word)
â—‹
╳ ╳
0 - - R/W NO 0 -
Target position (II) of X axis: P(II) (high word)
â—‹
â—‹ â—‹
0 - - R/W
NO
0 -
Upper bound of CAM synchronized output (high word)
╳
â—‹ â—‹
0 - - R/W
NO
0 -
D1843
PWM cycle setting on X axis (high word)
â—‹
╳ ╳
0 - - R/W
NO
0 -
D1844 Operation speed (II) of X axis: V(II) (low word)
D1845 Operation speed(II) of X axis: V(II) (high word)
â—‹ â—‹ â—‹
2,000 - - R/W
NO
2,000 -
Operation commands for X axis
â—‹ â—‹ â—‹
0 - 0 R/W
NO
0 3-53
D1846*
The enable setting of CAM (cyclic / acyclic)
â—‹ â—‹ â—‹
0 - 0 R/W
NO
0 -
D1847* Work modes for X axis
╳ ○ ○
0 - - R/W
NO
0 3-53
Current position of X axis: CP (pulse) (low word)
D1848
Slave position (low word)
â—‹ â—‹ â—‹
0 - - R/W
NO
0 -
Current position of X axis: CP (pulse) (high word)
D1849
Slave position (high word)
â—‹ â—‹ â—‹
0 - - R/W
NO
0 -
D1850 Current speed of X axis: CS (pps) (low word)
D1851 Current speed of X axis: CS (pps) (high word)
â—‹ â—‹
0 0 0 R/W
NO
0 -
D1852 Current position of X axis: CP (unit) (low word)
D1853 Current position of X axis: CP (unit) (high word)
â—‹
â—‹ â—‹
0 - - R/W
NO
0 -
D1854 Current speed of X axis: CS (unit) (low word)
D1855 Current speed of X axis:CS (unit) (high word)
â—‹
â—‹ â—‹
0 0 0 R/W
NO
0 -
D1856* Execution status of X axis
â—‹ â—‹ â—‹
0 - - R
NO
0 3-54
D1857* Error code of X axis
â—‹ â—‹ â—‹
0 - - R
NO
0 3-45
D1858 Numerator of electronic gear ratio of X axis
â—‹ â—‹ â—‹
- - - R/W
YES
1 -
D1859 Denominator of electronic gear ratio of X axis
â—‹ â—‹ â—‹
- - - R/W
YES
1 -
MPG input frequency on X axis (low word)
D1860
Master frequency (low word)
â—‹ â—‹ â—‹
0 0 - R/W
NO
0 -
D1861 MPG input frequency on X axis (high word)
â—‹ â—‹ â—‹
0 0 - R/W
NO
0 -