Chapter 12 Description of Parameter Settings
ME300
12.1-02-12
02-13
Multi-function Output 1 (Relay1)
Default: 11
02-16
Multi-function Output 2 (MO1)
Default: 0
Settings 0: No function
1: Indication during RUN
2: Operation speed reached
3: Desired frequency reached 1 (Pr.02-22)
4: Desired frequency reached 2 (Pr.02-24)
5: Zero speed (Frequency command)
6: Zero speed, includes STOP (Frequency command)
7: Over-torque 1 (Pr.06-0606-08)
8: Over-torque 2 (Pr.06-0906-11)
9: Drive is ready
10: Low voltage warning (Lv) (Pr.06-00)
11: Malfunction indication
13: Overheat warning (Pr.06-15)
14: Software brake signal indication (Pr.07-00)
15: PID feedback error (Pr.08-13, Pr.08-14)
16: Slip error (oSL)
17: Count value reached (Pr.02-20; does not return to 0)
18: Count value reached (Pr.02-19; returns to 0)
19: External interrupt B.B. input (Base Block)
20: Warning output
21: Over-voltage
22: Over-current stall prevention
23: Over-voltage stall prevention
24: Operation source
25: Forward command
26: Reverse command
29: Output when frequency Pr.02-34
30: Output when frequency < Pr.02-34
31: Y-connection for the motor coil
32: ∆-connection for the motor coil
33: Zero speed (actual output frequency)
34: Zero speed include STOP (output frequency)
35: Error output selection 1 (Pr.06-23)
36: Error output selection 2 (Pr.06-24)
37: Error output selection 3 (Pr.06-25)
38: Error output selection 4 (Pr.06-26)
40: Speed reached (including STOP)