Chapter 14 Fault Codes and Descriptions
ME300
No. Display on LED Keypad Fault Name Fault Descriptions
150
No-load current IO
measurement fault
(AUE6)
Fault on measuring no-load current IO.
Action and Reset
Action condition Software detection
Action time Immediately act
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Immediately reset
Record Yes
Cause Corrective Actions
Motor error Check if the motor works normally.
No. Display on LED Keypad Fault Name Fault Descriptions
151
dq axis inductance
measurement fault
(AUE7)
Fault on measuring dq axis inductance
Action and Reset
Action condition Software detection
Action time Immediately act
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Immediately reset
Record Yes
Cause Corrective Actions
Motor error Check if the motor works normally.
No. Display on LED Keypad Fault Name Fault Descriptions
152
High frequency
fault (AUE8)
Fault on measuring high frequency injection
Action and Reset
Action condition Software detection
Action time Immediately act
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Immediately reset
Record Yes
Cause Corrective Actions
Motor error Check if the motor works normally.