Chapter 6 Introduction of Parameters
6-3
6_
Explanation of paramters for special modules on the right of RTU-ECAT
Index Subindex Description
16#2000
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 1
st
one on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 1
st
one on the right of
RTU-ECAT.
16#2020
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 2
nd
one on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 2
nd
one on the right of
RTU-ECAT.
16#2040
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 3
rd
one on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 3
rd
one on the righ
t of
RTU-ECAT.
16#2060
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 4
th
one on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 4
th
one on the right of
RTU-ECAT.
16#2080
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 5
th
one on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 5
th
one on the right of
RTU-ECAT.
16#20A0
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 6
th
one on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 6
th
one on the right of
RTU-ECAT.
16#20C0
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 7
th
one
on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 7
th
one on the right of
RTU-ECAT.
16#20E0
16#1
The index and subindex that CR0 parameter corresponds to when
the special module is located as the 8
th
one on the right of
RTU-ECAT.
16#2
The index and subindex that CR1 parameter corresponds to when
the special module is located as the 8
th
one on the right of

Related product manuals