72
ENGLISH
GHDMIH
Symptom Cause/Solution Page
No audio is 
output with HDMI 
connection.
• Check the connection of the HDMI connectors.
• When  outputting  HDMI  audio  from  the  speakers,  set  “HDMI 
Audio Out” on the menu to “Amp”.
• When outputting HDMI audio from a TV, set “HDMI Audio Out” 
on the menu to “TV”.
14
51
51
No video is 
output with HDMI 
connection.
• Check the connection of the HDMI connectors.
• Set the input source to match the connected HDMI connector.
• Check  whether  the  TV  is  compatible  with  copyright  protection 
(HDCP). If connected to a device not compatible with HDCP, video 
will not be output correctly.
14
14, 19, 20
14
When the following 
operations are 
performed on 
devices compatible 
with HDMI control, 
the same operations 
occur on this unit.
• Power ON/OFF
• Switching  audio 
output devices
• Adjust volume
• Switch input source
• Set “HDMI Control” on the menu to “OFF”. To operate  power 
only for each device, set “Power Off Control” to “OFF”.
32, 51
GRadioH
Symptom Cause/Solution Page
Reception fails, or 
there is a lot of noise 
or distortion.
• Change the antenna orientation or position.
• Separate the AM loop antenna from the unit.
• Use an FM outdoor antenna.
• Separate the antenna from other connection cables.
18
18
18
18
GiPodH
Symptom Cause/Solution Page
iPod cannot be 
played.
• Check the iPod connections.
• Plug the control dock for iPod’s AC adapter into a power outlet.
• Switch the input source to “DOCK”.
18
–
19, 20
“Connection Error” 
is displayed.
• Unable to communicate properly. Turn off the power to this unit, 
disconnect the iPod and then reconnect it.
–
“Not Support” is 
displayed.
• The iPod connected to the  unit is not compatible. Please  make 
sure the iPod you are connecting is compatible.
• The software version of the connected iPod is an old one. Please 
update to the latest version.
21
–
“Connection Error” 
is displayed.
• The  iPod  is  not  responding.  Turn  off  the  power  to  this  unit, 
disconnect the iPod and then reconnect it.
–
GRemote control unitH
Symptom Cause/Solution Page
The set cannot be 
operated with the 
remote control unit.
• Batteries are worn out. Replace with new batteries.
• Operate the remote control unit within a distance of about 23 ft / 
7 m from this unit and at an angle of within 30°.
• Remove any obstacle between this unit  and the remote control 
unit.
• Insert the batteries  in the  proper direction, checking  the q  and 
w marks.
• The set’s remote control sensor is exposed to strong light (direct 
sunlight, inverter type fluorescent bulb light, etc.). Move the set 
to a place in which the remote control sensor will not be exposed 
to strong light.
64
64
64
64
64
Resetting the microprocessor
Perform this procedure if the display is abnormal or if operations cannot be performed.
When the microprocessor is reset, all the settings are reset to their default values.
SURROUND MODE 0
SURROUND MODE 1ON/STANDBY
1
Turn off the power using ON/STANDBY.
2
Press  ON/STANDBY  while  simultaneously  pressing  SURROUND  MODE  0  and 
SURROUND MODE 1.
3
Once  the  display  starts  ashing  at  intervals  of  about  1  second,  release  the  two 
buttons.
If in step 3 the display does not flash at intervals of about 1 second, start over from step 1.