Troubleshooting EN
72 / 84 03/2020
Number Description Procedure
I015 Tool lock on reject 1- The tool is locked forward after a NOK. 2- Unlock
the tool in function of the "lock on reject option" selec-
tion i.e. by reversing, loosening or input.
I016 Tool lock by Open Protocol 1- Tool has been locked by Open Protocol.
2- Unlock the tool by sending an "Enable tool" mes-
sage via Open Protocol.
I017 Loosening prohibited 1- Loosening is prohibited.
2- The loosening is disabled in the Assembly action.
3- The batch count type OK + NOK is used.
I021 Maximum retries reached 1- The maximum number of retries has been reached.
2- The tool is locked.
3- The running Assembly Process has to be aborted.
I022 Lock wait socket 1- The tool is locked. Put all sockets back and lift the
correct sockets combination.
I024 Loosening prohibited XML 1- Loosening is disabled by VWXML protocol.
I025 Tightening prohibited XML 1- Tightening is prohibited by VWXML protocol.
I040 Tool over speed 1- Motor speed exceeds 130% of its maximum value.
2- Check tool parameters (wrong motor tune parame-
ters).
3- Contact your Desoutter representative for support.
I042 Tool locked by GeoPositioning system 1- Tool has been locked by GeoPositioning system.
2- Unlock the tool by moving the tool in its defined
area.
I043 Tubenut maintenance 1- Tubenut settings need to be reconfigured.
2- Contact your Desoutter representative for proce-
dure.
I044 GeoTracking/Positioning learning mode ongoing 1- GeoTracking/Positioning learning mode.
I049 Access denied No procedure.
I050 Tool detection for pairing No procedure.
I051 ePOD connected ePOD connected.
I052 Incorrect network parameters Incorrect network parameters
I053 No Tightening Unit available No Tightening Unit available
I054 Pairing success No procedure.
I055 eDOCK already present on system No procedure.
I056 ePOD disconnected ePOD disconnected
I057 Pairing error No procedure.
I058 Tool locked by GeoTracking system 1- Tool has been locked by GeoTracking system.
2- Unlock the tool by moving the tool in its defined
area.
I059 New tool detected No procedure.
I060 Tool synchro ongoing No procedure.
I061 ExBC connection conflict 1- Two ExBC are configured with the same network
settings.
2- Verify communication ports and IP addresses.
I100 Cable ID invalid parameter 1- Invalid tool cable parameter.
2- Check that the tool cable is Desoutter certified.
3- Contact your Desoutter representative for support.
I101 Cable ID not detected 1- Tool cable communication error.
2- Check that the tool cable is Desoutter certified.
3- Contact your Desoutter representative for support.
I102 Cable ID not certified 1- Tool cable authentification error.
2- Check that the tool cable is Desoutter certified.
3- Contact your Desoutter representative for support.