EN Troubleshooting
03/2020 73 / 84
Number Description Procedure
I199 Console activated 1- The serial console is activated.
2- Warning: this console is dedicated to debug pur-
poses only and should not be used in production.
I202 Fieldbus lost 1- Fieldbus connection with PLC is lost.
- no heartbeat is received from PLC.
- the cable is broken or disconnected.
- the PLC is offline or not powered.
2- Check the Fieldbus configuration.
I204 Tool not validated 1- Tool locked by I/O.
2- Check I/O settings: "Tool validation" must be active
to unlock the tool.
I207 Assembly done 1- Assembly Process is done, the tool is locked.
2- Select a new Assembly Process to unlock the tool.
I208 Invalid run reverse parameter 1- Invalid Run Reverse setting: torque or speed are
greater than tool characteristics or loosening strategy is
not supported.
2- Check Pset settings with the current tool characteris-
tics.
3- Reduce the maximum number of turns.
I209 Pset invalid parameters 1 - Software internal error.
2 - Pset is corrupted. Try to transfer it again to the sys-
tem.
3 - If the error persists, contact your Desoutter repre-
sentative for support.
I215 Current calibration error 1- Current calibration failed.
2- Try once again.
3- If the problem occurs again, contact your Desoutter
representative for support.
I225 Error angle 1- Tool communication error.
2- Check tool and cable connections.
3- If the problem occurs again, contact your Desoutter
representative for support.
I226 Error torque 1- Tool communication error. Check tool and cable
connections.
2- Try once again.
3- If the problem occurs again, contact your Desoutter
representative for support.
I234 Fieldbus mismatch 1-The Fieldbus module declared in configuration is not
the same than the module connected to the system.
I237 Invalid data 1- The Fieldbus mapping has too many items.
I238 Invalid address 1- The device address affected to Fieldbus is invalid.
I239 Invalid communication settings 1- Fieldbus communication settings are invalid.
I241 CVINET FIFO alarm 1- CVINET FIFO has reached the alarm threshold, the
connection is lost.
2- Check the Ethernet cable.
3- Check the Ethernet configuration.
4- Check that CVINET is running correctly.
I242 ToolsNet FIFO alarm 1- ToolsNet FIFO has reached the alarm threshold, the
connection is lost.
2- Check the Ethernet cable.
3- Check the Ethernet configuration.
4- Check that ToolsNet is running correctly.
I244 Accessory disconnected 1- The accessory at the given address has been discon-
nected from the eBUS of the system.
2- Check the accessory cable.
I245 Wait report acknowledge 1- Acknowledge report with its corresponding input.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desoutter CONNECT Series and is the answer not in the manual?

Desoutter CONNECT Series Specifications

General IconGeneral
BrandDesoutter
ModelCONNECT Series
CategorySwitch
LanguageEnglish

Related product manuals