Number Description Procedure
E721 Up to 50 Pset: not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E722 Up to 250 Pset: not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E723 Up to 50 AP: not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E724 Up to 250 AP: not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E729 PFCS: demo expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E730 PFCS not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E732 VWXML: demo expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E733 VWXML not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E738 IPM: demo expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E739 IPM not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E890 Device Software Error -
E915 Inconsistent version 1- Firmware version of all systems must be identical.
2- Update the systems firmware.
E916 Workgroup not authorized 1- Connect an ePOD3 to the primary system.
E918 Emergency stop ! 1- The emergency stop has been activated.
2- Check the M8 connector.
E919 Additional transducer error 1- The additional transducer maximum torque is lower
than the embedded transducer maximum torque.
2- The Pset uses an additional transducer not installed
on the tool.
E927 Corrupted RIM information 1- It is not possible to use this RIM.
2- Contact your Desoutter representative for support.
E928 Tracking System communication failed 1- Tracking System communication failed.
E935 1 Working Space: demo expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E936 1 Working Space: not authorized 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E941 E-Lit WI-FI: demo mode expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desoutter CONNECT Series and is the answer not in the manual?

Desoutter CONNECT Series Specifications

General IconGeneral
BrandDesoutter
ModelCONNECT Series
CategorySwitch
LanguageEnglish

Related product manuals