Number Description Procedure
E277 Half DC bus voltage out of range 1- Half DC-bus voltage is out of range.
2- Switch off the system. Wait at least 30 seconds.
Switch on the system and try again.
3- If the problem occurs again, change the drive and
try again.
4- Contact your Desoutter representative for support.
E278 Pre-loaded BUS capacitors failure 1- Bus capacitors are not correctly pre-loaded.
2- Switch off the system. Wait at least 30 seconds.
Switch on the system.
3- If the problem occurs again, change the drive and
try again.
4- Contact your Desoutter representative for support.
E280 Result not stored 1- It was not possible to persist the tightening result on
ePOD.
2- Switch off the system. Wait at least 30 seconds.
Switch on the system.
3- Contact your Desoutter representative for support.
E502 CVILOGIX user info Message generated by CVILOGIX program.
E704 Missing UV 1- The UV amount of the configuration is greater than
the number of UVs available in the RIM.
2- Allocate UVs to this RIM.
3- Contact your Desoutter representative for more in-
formation.
E705 Missing demo UV 1- The demo UV amount of the configuration is
greater than the number of demo UVs available in the
RIM.
2- Allocate demo UVs to this RIM.
3- Contact your Desoutter representative for more in-
formation.
E706 Missing UV/demo UV 1- The demo UV amount of the configuration is
greater than the number of demo UVs available in the
RIM.
2- Allocate demo UVs to this RIM.
3- Contact your Desoutter representative for more in-
formation.
E711 Tightening Unit: demo mode expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E712 Tightening Unit not active 1 - This feature is configured but not active.
2 - To activate it with UV, go to the "feature manage-
ment" menu.
E717 Up to 50 Pset: demo mode expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E718 Up to 250 Pset: demo mode expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E719 Up to 50 AP: demo mode expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.
E720 Up to 250 AP: demo mode expired 1 - The demo period for this feature was 90 days.
2 - This demo period is now elapsed.
3 - To continue to use it you need to activate it with
UV.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desoutter CONNECT Series and is the answer not in the manual?

Desoutter CONNECT Series Specifications

General IconGeneral
BrandDesoutter
ModelCONNECT Series
CategorySwitch
LanguageEnglish

Related product manuals