D4204-EN Scale Link 2 Technical Manual 55
SAVTAR (D.A.N. 7267) SAVE TARE
ON = Indicator will save tare weight to non-volatile memory.
WT COM (D.A.N. 7268) WEIGHT COMPENSATION
Enables weight compensation functionality for scale platform A
AD FLT (D.A.N. 7269) AD FFT FILTERING
Enables A/D FFT filtering for scale platform A
CAL100 (D.A.N. 7271) FRACTIONAL WEIGHT CALIBRATION
Enables use of fractional CAL numbers for scale platform A
GAIN (D.A.N. 7272) GAIN
Select gain setting to be used for scale platform. (.75mv/v, 1.5mv/v, 3mv/v)
MENU 7.1 – SCALE SPECIFIC SETTINGS (SCALES A & B - JUMP LIST 71)
NOTE: Scale specific settings can be affected by the same global settings shown. When changed they will affect the currently selected scale.