DSF22 UNIQUE MONITORING TERMINAL
17
INSTALLATION AND SETUP GUIDE
Read actual ADC measurement
Description of parameters.
This section describes all parameters used in terminal. Each parameter can be accessed by SMS
commands, in case of need, parameter can be modified. Almost all parameters are stored in the non-
volatile memory, in case if power loss parameter value will not be changed.
P10 APN name
APN (Access Point Name), used to established GPRS communication. APN
is provided by GSM operator.
Parameter can be read and modified.
Any ASCII characters, maximal length 32 bytes
GET P10
To set parameter:
SET P10 internet
Response from device:
P10: internet
P11 IP address
Server IP address to send all data.
Parameter can be read and modified.
String of digits, separated by dots.
GET P11
To set parameter:
SET P11 192.168.100.101
Response from device:
P11: 192.168.100.101