DSF22 UNIQUE MONITORING TERMINAL
34
INSTALLATION AND SETUP GUIDE
P53 Valid fuel data wait time.
In case if fuel level will have major changes (fuel refill) during ignition is
switched on, fuel data procession algorithm will start accept new
measurements as new level reference. This parameter defines time
(seconds) after major level change, after that processing algorithm will
start to accept new measurements.
Parameter can be read and modified.
Not recommended to use value greater than 20, this can raise slow
reaction on fuel level changes during driving.
To read parameter:
GET P53
To set parameter:
SET P53 5
Response from device:
P53: 5
P60 Vehicle battery supervisor
This parameter enables/disables vehicle battery supervisor, it also defines
voltage threshold to trigger and send alert message.
Parameter can be read and modified.
0-99 – Vehicle battery supervisor disabled
100-250 – Vehicle battery supervisor enabled
Examples:
Value 100 equals to 10.0 Volts
Value 128 equals to 12,8 Volts
Value 245 equals to 24,5 Volts
GET P60
To set parameter:
SET P60 242
Response from device:
P60: 24.2V