DSF22 UNIQUE MONITORING TERMINAL
30
INSTALLATION AND SETUP GUIDE
P43 Fuel level change direction (Tank 1)
This parameter defines a fuel level change direction to trigger a fuel theft
alert for Tank 1. Parameter is related to ADC (Analog Digital Converter)
value, depending of vehicle’s fuel sensor type (normal or inverted),
required value must be selected.
Parameter can be read and modified.
0 – Fuel theft alert will be triggered in both cases (by increasing or
decreasing of ADC measurement)
1 – Fuel theft alert will be triggered only if ADC measurement will be
increased
2 – Fuel theft alert will be triggered only if ADC measurement will be
decreased
GET P43
To set parameter:
SET P43 2
Response from device:
P43: 2
P44 Fuel theft alarm activation time
This parameter defines activation time (seconds) for fuel theft alarm.
During this time terminal waits till fuel level becomes stable (after driving)
and remembers a current level to use it as reference.
Parameter can be read and modified.
0 – Activation time disabled, actual fuel level will be fixed right after
ignition switched off
1-250 – Activation time enabled, value equals to seconds for activation
time.
Maximal value allowed - 250
Not recommended to use value less than 10, it can raise fault alerts.
GET P44
To set parameter:
SET P44 30
Response from device:
P44: 30