P31 Fuel data source
This parameter defines a data source used to manage fuel consumption.
Terminal will use selected source to acquire fuel data and send to server.
Parameter can be read and modified.
0 – Specialized fuel sensor input used to get fuel data
1 – External analog input used to get fuel data
GET P31
To set parameter:
SET P31 1
Response from device:
P31: 1
P32 Fuel measurement frequency
This parameter defines a fuel measurement frequency during driving time
(Ignition is switched ON). Each unit equals to 32 milliseconds, if necessary
to calculate exact measurement frequency, use following formula:
Example 1 - To set measurement frequency once per second
1 second = 1000 milliseconds
1000/32 = 32.25 - used value must be 32
Example 2 - To set measurement frequency once per 5 seconds
5 seconds = 5000 milliseconds
5000/32 = 156.25 - used value must be 156
Parameter can be read and modified.
GET P32
To set parameter:
SET P32 50
Response from device:
P32: 50