DSF22 UNIQUE MONITORING TERMINAL
27
INSTALLATION AND SETUP GUIDE
P33 Fuel sensor imitation
Description
This parameter enable/disable fuel sensor imitation mode. In this mode
terminal will activate digital output during fuel data measuring.
See section “Fuel sensor imitation mode”.
Options
Parameter can be read and modified.
Used values
0 Fuel sensor imitation disabled
1 Fuel sensor imitation enabled
Default value
0
Comments
Example
To read parameter:
GET P33
To set parameter:
SET P33 1
Response from device:
P33: 1
P35 Universal digital pin working mode
Description
This parameter defines universal digital pin (green wire) working mode it
can work as digital input or digital output.
Options
Parameter can be read and modified.
Used values
0 Universal digital pin is configured as digital input
1 Universal digital pin is configured as digital output
Default value
0
Comments
Example
To read parameter:
GET P35
To set parameter:
SET P35 1
Response from device:
P35: 1