DSF22 UNIQUE MONITORING TERMINAL
27
INSTALLATION AND SETUP GUIDE
P33 Fuel sensor imitation
This parameter enable/disable fuel sensor imitation mode. In this mode
terminal will activate digital output during fuel data measuring.
See section “Fuel sensor imitation mode”.
Parameter can be read and modified.
0 – Fuel sensor imitation disabled
1 – Fuel sensor imitation enabled
GET P33
To set parameter:
SET P33 1
Response from device:
P33: 1
P35 Universal digital pin working mode
This parameter defines universal digital pin (green wire) working mode – it
can work as digital input or digital output.
Parameter can be read and modified.
0 – Universal digital pin is configured as digital input
1 – Universal digital pin is configured as digital output
GET P35
To set parameter:
SET P35 1
Response from device:
P35: 1