DSF22 UNIQUE MONITORING TERMINAL
28
INSTALLATION AND SETUP GUIDE
P36 Digital output 2
This parameter defines condition of digital output Nr2. It is useful in cases
when some of vehicle’s equipment (autonomous heating system, lights,
etc.) must be activated remotely.
Note!!!
Digital output can be activated/deactivated only if is universal digital pin
is set to output work mode.
Parameter can be read and modified.
0 – Digital output deactivated
1 – Digital output activated
In case of terminal power loss or restart, this parameter will be set to 0
To read parameter:
GET P36
To set parameter:
SET P36 1
Response from device:
P36: 1
P40 Fuel theft alarm (Tank 1)
This parameter defines a work mode for fuel theft alarm for Tank 1. In case
if set to 0, then fuel theft alarm is disabled. In parameter is greater than 0,
then fuel theft alarm becomes enabled, value equals to threshold of level
changes to trigger fuel theft alert. Greater value = less “sensitivity”
Parameter can be read and modified.
0 – Fuel theft alarm disabled.
1-250 – Fuel theft alarm enabled, trigger threshold value set
Maximal value allowed - 250
GET P40
To set parameter:
SET P40 2
Response from device:
P40: 2