DSF22 UNIQUE MONITORING TERMINAL
32
INSTALLATION AND SETUP GUIDE
P48 User phone number Nr2
Description
This parameter defines a user Nr2 phone number for SMS alert reception.
Options
Parameter can be read and modified.
Used values
ASCII digits 0-9, maximal length is 32 bytes
Note!!!
Phone number must be entered with “+” sign and country code,
otherwise SMS alert will not be sent.
Default value
(empty)
Comments
Example
To read parameter:
GET P48
To set parameter:
SET P48 +37198765432
Response from device:
P48: +37198765432
P50 Fuel data processing
Description
This parameter enables/disables fuel data processing. In case if set to 0,
fuel data processing is disabled, row fuel data will be sent to server. In case
if set to 1, fuel data will be processed using special algorithm.
Options
Parameter can be read and modified.
Used values
0 Fuel data procession disabled
1 Fuel data procession enabled
Default value
1
Comments
Example
To read parameter:
GET P50
To set parameter:
SET P50 0
Response from device:
P50: 0