26
H1/12 ORANGE (-) ground-when-armed output
This wire supplies a (-)500 mA ground as long as the system is armed. This output ceases as soon as the
system is disarmed. The GWA can be hooked up to a window control module, a voice module or any accessory
that requires a ground when armed.
secondary harness (H2) wire connection guide
H2/1 LIGHT BLUE (-) 200mA 2nd unlock output
This wire provides a second unlock output for progressive locks. Refer to document 1041—Door Locking
System Wiring Guide for specific applications.
H2/2 WHITE/BLACK 200 mA (-) programmable channel 5 output
This wire provides 200 mA programmable output. (See Feature Descriptions section of this guide.)
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! This transistorized
output can only supply 200 mA, and connecting directly to a solenoid, motor, or other high-current device
will cause the module to fail.
H2/3 VIOLET/BLACK 200 mA (-) programmable channel 4 output
This wire provides 200 mA programmable output. (See Feature Descriptions section of this guide.)
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! This transistorized
output can only supply 200 mA, and connecting directly to a solenoid, motor, or other high-current device
will cause the module to fail.