Service - 96 C16x/C24x/C30x Operators Manual
100 Hour Service
Change Air Filter Elements
C16x
Change air filter element every 100 hours.
To change:
1. Remove wing nuts and air cleaner cover.
2. Remove filter element and replace it.
3. Install air cleaner cover.
4. Tighten wing nuts.
C24x and C30x
Change air filter element every 100 hours.
To change:
1. Remove air filter cover.
2. Remove filter elements and replace them.
3. Install air filter cover.
NOTICE: Cleaning can damage the filter
elements.
Do not tap filter elements to loosen dirt.
Do not use compressed air or water.
Replace the elements.
NOTICE: Cleaning can damage the filter
elements.
Do not tap filter elements to loosen dirt.
Do not use compressed air or water.
Replace the elements.